Leading Manufacturers, Exporters, Wholesaler, Retailer of Combo Dust Sampler - VCDS 329, Combo Dust Sampler - VCDS 230, Combo Dust Sampler - VCDS 320 and Combo Dust Sampler - VCDS 401 from Ahmedabad.
| Business Type | Manufacturer, Exporter, Supplier, Retailer |
| Type | Dust Samplers, COMBO DUST SAMPLER |
| Weight | Approximate 29 Kg |
| Voltage | 220V |
| Condition | New |
| Power Source | Electricity |
| Features | Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design |
| Warranty | 14 MONTH |
| Display | Ananlog |
| Flow Rate | PM2.5 & PM10 at a constant 1m3/hr unaffected by voltage fluctuation and filter chocking through critical orifice.Gaseous Pollutant–4inlet & 1 outlet with needle valves for flow control of each unit |
| Automation Grade | Manual |
| Brand Name | VAIBHAV |
| Usage | AMBIENT AIR SAMPLING |
| Power | AC |
| Power Supply | 220 VAC |
| Certificate | CALIBRATION CERTIFICATE |
| Color | WHITE |
| PM 2.5 Size Separator | Two stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR |
| PM 10 Size Separator | Single stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom. |
| Filter Media | 47 mm diameter Filter in a Filter Cassette housed in each stream of filter holder assembly |
| Flow Meter | Independent Diaphragm gas meter for PM 2.5 & PM 10 record the total air volume sampled with a accuracy of 200 ML in each stream & acrylic body rotameter for gaseous pollutant sampling |
| Clock / Timer System | Programmable Real Time control system with control of automatic start & stop of instrument |
| Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. |
| Operation | Up-to 28 hours continuously |
| Time totalizer | 0 to 9999.99 hours recorded on a digital time totalizer |
| Product Code | VCDS 320 |
| Port | AHMEDABAD |
| Payment Terms | L/C, D/P, T/T |
| Delivery Time | READY STOCK |
special features
| Business Type | Manufacturer, Exporter, Supplier, Retailer |
| Type | Dust Samplers, COMBO DUST SAMPLER - MULTI PARAMETER DUST SAMPLER |
| Weight | 30-40kg, 35 Kg |
| Voltage | 220V |
| Condition | New |
| Features | Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design |
| Warranty | 14 MONTHS |
| Display | Ananlog |
| Flow Rate | 1m3 CONSTANT |
| Automation Grade | Manual |
| Brand Name | Vaibhav |
| Usage | Pm 2.5 (fpm), Pm 10(rspm) & Gaseous Pollutant Sampling |
| Power | 220 VAC |
| Power Supply | AC |
| PM 2.5 Size Separator | Two stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR |
| PM 10 Size Separator | Single stage impactor matching to European Design (According to EN 12341), sample collected on standard glass micro fiber filter paper of 47mm diameter. |
| Filter Media | : 47 mm diameter Filter in a Filter Cassette housed in each stream of filter holder assembly. |
| Flow Rate (PM 2.5) | constant 1m3/hour unaffected by voltage fluctuation & filter chocking through critical orifice. |
| Flow Rate (PM 10) | constant 2.3m3/hour unaffected by voltage fluctuation and filter chocking through critical orifice |
| Flow Rate (GAS) | Four inlet & one outlet with needle valves for flow control of each unit through 0.3 to 3.0 LPM acrylic body rotameter |
| Flow Meter | Independent Diaphragm gas meter for PM2.5 & PM10 record total air volume sampled with a accuracy of 200ml in each stream to measure air sampling flowrate & acrylic body Rotameter for gaseous pollutant |
| Clock / Timer System | Programmable Real Time control system with control of automatic start & stop of instrument |
| Size, Weight & Cabinet | Size : 610 X 180 X 425 Weight : Approximate 34 Kg, Cabinet : Two Part Modular, Corrosion free, lockable and easy to transport |
| Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. |
| Operation | Up-to 28 hours continuously |
| Time Totalizer | 0 to 9999.99 hours recorded on a digital time totalizer |
| Sampling Train | Four inlet and one outlet manifold with built in needle valve for flow control of each inlet. 4 Nos. of 35ml borosilicate glass Impingers for gaseous sampling |
| WARRANTY | ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY |
| Product Code | VCDS 230 |
| Payment Terms | L/C, D/P, T/T |
Special Features :
| Business Type | Manufacturer, Exporter, Supplier, Retailer |
| Weight | 29 KG |
| Brand Name | Vaibhav |
| Production Capacity | 100 Set Per year |
| Airflow | PM 2.5 - 1.0 M3/HR, PM 10 - 2.3M3/HR |
| Dimension (L*B*H in mm) | 300 X 460 X (650 + 250) |
| Energy Consumption | Single Phase , 220V AVC, 2 AMP, |
| Warranty | 1 Year |
| Product Code | VCDS320 |
| Port | EX WORK AHMEDABAD |
| Payment Terms | T/T |
| Delivery Time | READY STOCK |
| Packaging Details | Standard Packing in Plastic Coated Hard Board with Armor Sheet Protection and Bubble Roll Layer On Instrument |
Special Features :
| Business Type | Manufacturer, Exporter, Supplier, Retailer |
| Type | Dust Samplers |
| Weight | 20-30kg, 29 KG |
| Voltage | 220V |
| Condition | New |
| Features | Durable, Eco Friwndly, Fast Cleaning, Fine Finished, Precise Design |
| Warranty | 14 MONTH |
| Display | Ananlog |
| Automation Grade | Manual, Semi Automatic |
| Brand Name | Vaibhav |
| Power | 220 VC AC 50 Hz |
| Production Capacity | 100 Set Per year |
| Airflow | PM 2.5 - 1.0 M3/HR, PM 10 - 2.3M3/HR |
| Dimension (L*B*H in mm) | 540 X 480 X 480 |
| Energy Consumption | Single Phase , 220V AVC, 2 AMP, |
| PM 2.5 Size Separator | : Two stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR |
| PM 10 Size Separator | Single stage impactor matching to European Design (According to EN 12341), sample collected on standard glass micro fiber filter paper of 47mm diameter. |
| Filter Media | 47 mm diameter Filter in a Filter Cassette housed in each stream of filter holder assembly. |
| Flow Rate (PM 2.5) | PM 2.5 at a constant 1m3/hour |
| Flow Rate (PM 10) | PM 10 at a constant 2.3m3/hour unaffected by voltage fluctuation and filter chocking through critical orifice |
| Flow Rate (GAS) | Gaseous Pollutant – Four inlet & one outlet with needle valves for flow control of each unit through 0.3 to 3.0 LPM acrylic body rotameter |
| Flow Meter | Independent Diaphragm gas meter for PM 2.5 & PM 10 record the total air volume sampled with a accuracy of 200 ML in each stream & acrylic body rotameter for gaseous pollutant sampling |
| Clock / Timer System | Programmable Real Time control system with control of automatic start & stop of instrument |
| Dimension & Weight | Dimension(mm) : LXBXH – 540X480X480 Weight : Approximate 29 Kg |
| Power Requirement | Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. |
| Operation | Up-to 28 hours continuously |
| Time totalizer | 0 to 9999.99 hours recorded on a digital time totalizer |
| Sampling Train | 4 Nos. of 35ml borosilicate glass Impingers for gaseous sampling |
| WARRANTY | ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY |
| Product Code | VCDS 401 |
| Port | EX WORK AHMEDABAD |
| Payment Terms | L/C, D/P, T/T, Other |
| Delivery Time | READY STOCK |
| Packaging Details | Standard Packing in Plastic Coated Hard Board with Inside Armor Sheet Protection and Bubble Roll Layer On Instrument |
Special Features :
Raise your Query
Hi! Simply click below and type your query.
Our experts will reply you very soon.